Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
J. vasc. bras ; 12(1): 16-24, jan.-mar. 2013. ilus, tab
Article in English | LILACS | ID: lil-670384

ABSTRACT

PURPOSE: To report initial findings with the GORE Flow Reversal System®, with a focus on major/minor adverse events in the 30 first postoperative days. METHODS: The first 24 patients submitted to carotid angioplasty using the GORE system, from June 2010 to May 2012, were retrospectively assessed with regard to indications, anatomic details, technical difficulties, and early clinical outcomes, including major (stroke, death, acute myocardial infarction) and minor (hematoma) adverse events. RESULTS: Systemic hypertension was present in 100% of the patients, diabetes mellitus in 58.3%, and coronary disease in 37.5%. Type II aortic arch was encountered in 62.5% of the patients and atherosclerotic lesion predominantly at the carotid bifurcation affecting the internal and common carotid arteries in 79.2%. Angiographic data revealed contralateral carotid arteries with <50% stenosis in 95.8% of cases and preservation of cerebral blood flow in 95.8%. All procedures but one were technically successful. Mean cerebral flow reversal time was 14.9 minutes, with a statistically significant difference between the first 12 (17.9 minutes) and the last 12 patients treated (11.6 minutes) (p<0.001). Intolerance to flow reversal was observed in 17.4% of the cases. Technical difficulties were experienced in 1 patient (4.2%). Clinical outcomes included 4.2% of stroke and 12.5% of hematomas at arterial puncture sites. CONCLUSION: The system was technically effective. A significant reduction in cerebral flow reversal time was observed, and the rates of early major/minor adverse events were within acceptable limits, suggesting that the device is safe and effective.


OBJETIVO: Relatar os achados iniciais da utilização do GORE Flow Reversal System® (Sistema de Fluxo de Reversão), com foco em eventos adversos maiores/menores nos primeiros 30 dias do pós-operatório. MÉTODOS: Os primeiros 24 pacientes submetidos a angioplastia carotídea com a utilização do sistema GORE, de junho de 2010 a maio de 2012, foram avaliados retrospectivamente com relação a indicações, detalhes anatômicos, dificuldades técnicas e desfechos clínicos imediatos, incluindo eventos adversos maiores (acidente vascular cerebral, morte, infarto agudo do miocárdio) e menores (hematoma). RESULTADOS: Hipertensão sistêmica estava presente em 100% dos pacientes, diabete melito em 58,3% e doença coronariana em 37,5%. Arco aórtico tipo II foi encontrado em 62,5% dos pacientes e lesão de aterosclerose predominantemente na bifurcação carotídea que afeta as artérias carótidas internas e comuns em 79,2%. Dados angiográficos revelaram artérias carótidas contralaterais com estenose <50% em 95,8% de casos e preservação de fluxo sanguíneo cerebral em 95,8%. Todos os procedimentos, com exceção de um, foram tecnicamente bem sucedidos. A média do tempo de reversão do fluxo cerebral foi de 14,9 minutos, com uma diferença estatisticamente significativa entre os primeiros 12 pacientes (17,9 minutos) e os últimos 12 pacientes tratados (11,6 minutos) (p<0,001). Intolerância à reversão de fluxo foi observada em 17,4% dos casos. Ocorreram dificuldades técnicas em 1 paciente (4,2%). Desfechos clínicos incluíram 4,2% de acidente vascular cerebral e 12,5% de hematomas em locais de punção arterial. CONCLUSÃO: O sistema foi tecnicamente eficaz. Uma redução significativa no tempo de reversão do fluxo cerebral foi observada e as taxas de eventos adversos maiores/menores ficaram dentro de limites aceitáveis, sugerindo que o dispositivo é seguro e eficaz.


Subject(s)
Humans , Aged , Carotid Artery, External/anatomy & histology , Carotid Artery Diseases/prevention & control , Carotid Stenosis/prevention & control , Angioplasty/methods , Cerebrum/anatomy & histology
2.
Rev. argent. cir. cardiovasc. (Impresa) ; 10(1): 40-44, ene-abr. 2012. ilus
Article in Spanish | LILACS | ID: lil-730174

ABSTRACT

La resolución de la patología del arco aórtico constituye un desafío quirúrgico. En el presente reporte se describen 3 casos, detallando las estrategias utilizadas en nuestro servicio para reemplazar el arco cuando se debe asociar a reemplazo de aorta ascendente por esternotomía o cuando se requiere reemplazo simultáneo de aorta descendente por toracotomía.


A resoluçâo da patologia do arco aórtico constitui um desafio cirúrgico. No presente relato descrevem-se 3 casos, detalhando as estratégias utilizadas em nosso serviço para substituir o arco quando e deve associar a substituiçâo da aorta ascendente por esternotomía ou quando é necessária uma substituiçâo da aorta descendente por toracotomía.


The resolution of aortic arch disease is a surgical challenge. This report describes 3 cases indicating the strategies used in our department to replace the arch combining the replacement of the ascending aorta by sternotomy or when it is necessary to simultaneously replace the descending aorta by thoracotomy.


Subject(s)
Humans , Male , Female , Aged , Aortic Aneurysm, Thoracic/surgery , Aorta, Thoracic/pathology , Sternotomy , Thoracic Surgical Procedures
3.
J. vasc. bras ; 8(4): 307-312, dez. 2009. ilus
Article in Portuguese | LILACS | ID: lil-543397

ABSTRACT

Contexto: A qualidade e a quantidade de partículas coletadas em filtros de proteção cerebral (FPC) durante angioplastia transluminal percutânea com stent (ATPS) podem esclarecer a importância desses dispositivos no tratamento de estenoses carotídeas. Objetivos: Analisar o conteúdo retido por FPC em pacientes submetidos a ATPS de artéria carótida interna com nova técnica de análise qualiquantitativa. Métodos: O material coletado em 10 FPC durante ATPS da bifurcação da carótida em pacientes com alto risco cirúrgico foi submetido a análise microscópica qualiquantitativa. Fotografias digitais das lâminas com material corado com hematoxilina e eosina foram analisadas com o programa Axio Vision LE Release 4.1, que calculou a área das partículas em micrômetros/metro quadrado (µm²). Resultados: O exame histopatológico evidenciou material em 100 por cento dos filtros consistindo predominantemente de restos hemáticos, cristais de colesterol e cálcio. A área média de fragmentos coletados foi expressiva (1.570.310 µm²), e houve ampla variância desses valores. Conclusões: Os FPC coletam quantidade importante de fragmentos de placas de ateroma, e a grande variância nas quantidades de material coletado pode estar associada com a gravidade da lesão, motivo pelo qual se tornam relevantes estudos que utilizem técnica padronizada para a quantificação desses fragmentos e para a compreensão de seu real significado clínico.


Background: Quality and quantity of the content retained in embolic protection filters (EPFs) used in percutaneous transluminal angioplasty and stenting may possibly indicate the importance of EPFs in the management of carotid stenosis. Objectives: To analyze the content retained by EPFs in patients undergoing percutaneous transluminal angioplasty and stenting of the internal carotid artery using a new technique for qualitative and quantitative analysis. Methods: Material captured in 10 EPFs during percutaneous transluminal angioplasty and stenting in high-surgical-risk patients was examined to determine a qualitative and quantitative microscopic analysis. Digital photographs of the hematoxylin-eosin stained slides were analyzed using the Axio Vision LE Release 4.1 software in order to calculate the particles area in micra/square meter (µm²). Results: Histopathological examination identified particulate debris in 100 percent of the filters including predominantly blood residues, cholesterol crystals, and calcium Quantity of captured fragments was significant (mean of 1,570,310 µm²) with a wide range of these values. Conclusions: Significant quantity of fragments of atheromatous plaques is retained by EPFs and the wide range in the quantity of the retained debris can be associated with the lesion severity; therefore new studies using standardized technique for quantifying these fragments and for better understanding their real clinical meaning are necessary.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Carotid Arteries , Endarterectomy/methods , Endarterectomy , Carotid Stenosis/complications , Carotid Stenosis/diagnosis , Stents
SELECTION OF CITATIONS
SEARCH DETAIL